Neverfail Heartbeat Monitor Reports Neverfail for Exchange Attributes Errors in Windows System Log

Follow

Summary

This Knowledgebase article describes a known issue with Neverfail for Exchange.


More Information

Symptom

The following are examples of errors that may appear in the Windows Application log after starting the Neverfail Heartbeat monitor service.

  1. Cannot find RPCRequests (0x80041010) in Windows Management Instrumentation
  2. Failed to obtain a value for attribute RPC Requests, Instance:
    Win32_PerfRawData_MSExchangeIS_MSExchangeIS=@ from Windows Management
    Instrumentation
  3. Unable to query attribute RPC Requests, Instance:
    Win32_PerfRawData_MSExchangeIS_MSExchangeIS=@ (0xFFFFFFFF). Ignoring this
    attribute until Neverfail Monitor Service is restarted or reconfigured. This
    error indicates that the attribute is not available from WMI. To verify the
    existence of this attribute, use perfmon /wmi. This error may indicate that an
    application or its management interface is not correctly installed. It could
    also indicate that the WMI service is not responding, in which case the WMI
    service and the Neverfail Monitor service should be restarted.
  4. Cannot find SendQueueSize (0x80041010) in Windows Management Instrumentation
  5. Failed to obtain a value for attribute Send Queue Size, Instance:
    Win32_PerfRawData_MSExchangeIS_MSExchangeISMailbox.Name="_Total" from Windows
    Management Instrumentation
  6. Unable to query attribute Send Queue Size, Instance:
    Win32_PerfRawData_MSExchangeIS_MSExchangeISMailbox.Name="_Total" (0xFFFFFFFF).
    Ignoring this attribute until Neverfail Monitor Service is restarted or
    reconfigured. This error indicates that the attribute is not available from
    WMI. To verify the existence of this attribute, use perfmon /wmi. This error
    may indicate that an application or its management interface is not correctly
    installed. It could also indicate that the WMI service is not responding, in
    which case the WMI service and the Neverfail Monitor service should be
    restarted.

Cause

It is possible for a fresh install of Exchange not to register the WMI counters correctly.

Resolution

To resolve this issue, follow the steps below:

  1. Click Start -> Run .
  2. In the resulting dialog, type 'cmd', and then click OK .
  3. At the command prompt, type the following command as appropriate for your operating system, and then press ENTER :
    • Microsoft Windows Server 2003
    • Microsoft Windows 2000
  4. wmiadap.exe /f

    winmgmt /resyncperf

  5. At the command prompt, type 'exit', and then press ENTER to close the command prompt.


Applies To

Neverfail for Exchange All Versions


Related Information

None

KBID-1171