Summary
This Knowledgebase article provides the procedure to perform a single node upgrade in the event that an attempt to upgrade a pair/trio fails leaving a single node that was not upgraded.
More Information
When performing an upgrade, should the upgrade of servers fail leaving a single node that was not successfully upgraded, perform the following procedure to add a Management IP address to the server and perform a single node upgrade.
From Neverfail IT Continuity Engine v7.1(or higher) to any of the following (were applicable):
- Neverfail IT Continuity Engine v7.1.2 (or higher)
- Neverfail Continuity Engine v8.1 (or higher)
For Neverfail Engine v7.x or v8.x with any OS except Windows Server 2008 R2 SP0:
Add a Management IP address to the Secondary/Tertiary Neverfail Engine server that failed to upgrade.
Perform the following steps:
- Navigate to MS Windows -> Control Panel -> Network and Sharing Center.
- Click on Change Adapter Settings.
- Right-click the intended Network Interface Card (NIC) and select Properties.
- Select Internet Protocol Version 4 (TCP/IPv4) and then click Properties.
- Click Advanced.
- Click Add to display the TCP/IP Address dialog.
- Enter the Management IP address (in the same subnet as the Public IP address) and subnet mask.
- Click Add.
- Click OK -> OK -> Close.
- Perform a Single Node Upgrade.
- Launch the Neverfail Engine Management Service (EMS).
- Add the cluster in EMS if not already present.
- Select the cluster and navigate to Manage -> Deploy -> Upgrade the selected server.
- Add the built-in administrator account.
- Select the I confirm that no users are logged on to the P/S/T server.
- Select the Upgrade only a specific server in the cluster option.
- Add the Management IP and click Next.
- After validation, click Finish to perform the single node upgrade.
When the Operating System is Windows Server 2008 R2 SP0 without Hotfix (2386184):
Add a Management IP address to the Secondary/Tertiary Neverfail Engine server running on Windows Server 2008 R2 SP0 that failed to upgrade.
- Download the cloak.zip file, extract it, and copy it to the <%neverfail_install_location%>\R2\bin folder.
- Open a command window and navigate to the <%neverfail_install_location%>\R2\bin folder.
- Enter the following command:
cloak.exe install
- Navigate to MS Windows -> Control Panel -> Network and Sharing Center.
- Click on Change Adapter Settings.
- Right-click the intended Network Interface Card (NIC) and select Properties.
- Select Internet Protocol Version 4 (TCP/IPv4) and then click Properties.
- Click Advanced.
- Click Add to display the TCP/IP Address dialog.
- Enter the Management IP address and subnet mask.
- Click Add.
- Click OK -> OK -> Close.
- Perform a Single Node Upgrade.
- Launch the Neverfail Engine Management Service (EMS).
- Add the cluster in EMS if not already present.
- Select the cluster and navigate to Manage -> Deploy -> Upgrade the selected server.
- Add the built-in administrator account.
- Select the I confirm that no users are logged on to the P/S/T server.
- Select the Upgrade only a specific server in the cluster option.
- Add the Management IP and click Next.
- After validation, click Finish to perform the single node upgrade.
From Neverfail IT Continuity Engine v7.0 to any of the following:
- Neverfail IT Continuity Engine v7.1.2 (or higher)
- Neverfail Continuity Engine v8.1 (or higher)
For Neverfail IT Continuity Engine v7.0 with any OS except Windows Server 2008 R2 SP0:
Add a Management IP address to the Secondary/Tertiary Neverfail Engine server that failed to upgrade.
Perform the following steps:
- Open a command window.
- To add a Management IP address, enter the following command:
netsh interface ipv4 add address <adapterName> <ip> <mask> skipassource=true
- The Management IP address is added to the server.
- Perform a Single Node Upgrade.
- Launch the Neverfail Engine Management Service (EMS).
- Add the cluster in EMS if not already present.
- Select the cluster and navigate to Manage -> Deploy -> Upgrade the selected server.
- Add the built-in administrator account.
- Select the I confirm that no users are logged on to the P/S/T server.
- Select the Upgrade only a specific server in the cluster option.
- Add the Management IP and click Next.
- After validation, click Finish to perform the single node upgrade.
When the Operating System is Windows Server 2008 R2 SP0 without Hotfix (2386184):
Add a Management IP address to the Secondary/Tertiary Neverfail Engine server running on Windows Server 2008 R2 SP0 that failed to upgrade.
- Download the cloak.zip file, extract it, and copy it to the <%neverfail_install_location%>\R2\bin folder.
- Open a command window and navigate to the <%neverfail_install_location%>\R2\bin folder.
- Enter the following command:
cloak.exe install
- Navigate to MS Windows -> Control Panel -> Network and Sharing Center.
- Click on Change Adapter Settings.
- Right-click the intended Network Interface Card (NIC) and select Properties.
- Select Internet Protocol Version 4 (TCP/IPv4) and then click Properties.
- Click Advanced.
- Click Add to display the TCP/IP Address dialog.
- Enter the Management IP address and subnet mask.
- Click Add.
- Click OK -> OK -> Close.
- Perform a Single Node Upgrade.
- Launch the Neverfail Engine Management Service (EMS).
- Add the cluster in EMS if not already present.
- Select the cluster and navigate to Manage -> Deploy -> Upgrade the selected server.
- Add the built-in administrator account.
- Select the I confirm that no users are logged on to the P/S/T server.
- Select the Upgrade only a specific server in the cluster option.
- Add the Management IP and click Next.
- After validation, click Finish to perform the single node upgrade.
From Neverfail Heartbeat v6.7 to any of the following:
- Neverfail IT Continuity Engine v8.0
-
Neverfail Continuity Engine v8.1 (or higher)
For Neverfail Heartbeat v6.7[.n] with any supported OS except Windows Server 2008 R2 SP0:
Add a Management IP address to the Secondary/Tertiary Neverfail Heartbeat server that failed to upgrade.
Perform the following steps:
- Open a command window.
- To add a Management IP address, enter the following command:
netsh interface ipv4 add address <adapterName> <ip> <mask> skipassource=true
- The Management IP address is added to the server.
- Ensure the nfserverr2 service is stopped on the passive node prior to starting the upgrade if the Fileserver plug-in is installed.
- Ensure that the lanmanserver service is started on the node prior to starting the upgrade.
- Perform a Single Node Upgrade.
- Launch the Neverfail Engine Management Service (EMS).
- Add the cluster in EMS if not already present.
- Select the cluster and navigate to Manage -> Deploy -> Upgrade the selected server.
- Add the built-in administrator account.
- Select the I confirm that no users are logged on to the P/S/T server.
- Select the Upgrade only a specific server in the cluster option.
- Add the Management IP and click Next.
- After validation, click Finish to perform the single node upgrade.
When the Operating System is Windows Server 2008 R2 SP0 without Hotfix (2386184):
Add a Management IP address to the Secondary/Tertiary Neverfail server running on Windows Server 2008 R2 SP0 that failed to upgrade.
- Download the cloak.zip file, extract it, and copy it to the <%neverfail_install_location%>\R2\bin folder.
- Open a command window and navigate to the <%neverfail_install_location%>\R2\bin folder.
- Enter the following command:
cloak.exe install
- Navigate to MS Windows -> Control Panel -> Network and Sharing Center.
- Click on Change Adapter Settings.
- Right-click the intended Network Interface Card (NIC) and select Properties.
- Select Internet Protocol Version 4 (TCP/IPv4) and then click Properties.
- Click Advanced.
- Click Add to display the TCP/IP Address dialog.
- Enter the Management IP address and subnet mask.
- Click Add.
- Click OK -> OK -> Close.
- Ensure the nfserverr2 service is stopped on the passive node prior to starting the upgrade if the Fileserver plug-in is installed.
- Ensure that the lanmanserver service is started on the node prior to starting the upgrade.
- Perform a Single Node Upgrade.
- Launch the Neverfail Engine Management Service (EMS).
- Add the cluster in EMS if not already present.
- Select the cluster and navigate to Manage -> Deploy -> Upgrade the selected server.
- Add the built-in administrator account.
- Select the I confirm that no users are logged on to the P/S/T server.
- Select the Upgrade only a specific server in the cluster option.
- Add the Management IP and click Next.
- After validation, click Finish to perform the single node upgrade.
Applies To:
Neverfail Heartbeat v6.7[.n]
Neverfail IT Continuity Engine v7.0[.n], v7.1[.n]
Neverfail IT Continuity Engine v8.0
Neverfail Continuity Engine v8.1 or higher
Related Information:
cloak.zip
KBID-2886