This Knowledge base article provides information about how to configure Neverfail for Progress MOVEit Automation Plug-in to remove MOVEit Automation cache directory from the replication data set.
MOVEit Automation cache directory is used to store files while they are being processed by a task; files will automatically be deleted from here when related tasks complete.
MOVEit Automation cache directory is automatically included by Neverfail for MOVEit Automation plugin in the protected data set: a corresponding inclusion file filter is automatically defined by the plugin, i.e. C:\TEMP\MIC\** for default configurations, thus if a failover occurs while transactions are in progress, the contents of cache directory would be synced to the passive nodes.
In the situations where a MOVEit Automation task processes very large files (e.g. ~50GB), Neverfail Engine data replication might take too long while the processed files are being written inbound, moved to the MOVEit Automation cache directory and replicated at the same time. A way to avoid this scenario is to remove the cache directory from the Neverfail Engine data replication set, as described in the following procedure.
To remove the MOVEit Automation cache directory corresponding file filter one should do the following:
Neverfail for Progress MOVEit Plug-ins